High pressure adsorption measurements are important in the fields of carbon dioxide sequestration, methane storage, hydrogen storage, and gas separation. The iSorb-HP instruments (volumetric sorption apparatus) generate automatic measurements of full adsorption and desorption isotherms over a wide range of pressures and temperatures.The iSorb series is a family of four such high pressure sorption analyzers; one and two-sample models each available with an upper pressure limit of 100bar or 200bar, complete with built in vacuum pumps and sample degassing capability. All models feature pressure transducers both in the dosing manifold and on the sample cell for maximum sensitivity; this also provides the iSorb-HP2 model the capability to simultaneously analyze two samples.Measurements are defined in terms of pressure or dose amount for both adsorption and desorption, equilibrium criteria, sample temperature (according to the heating /cooling device selected) and choice of equation of state (EoS)*:
Request a quote click hereHigh pressure gas sorption analyzer, the iSorb HP
  • Schmidt-Wenzel type, defined in terms of Helmholtz free energy (NIST recommended)
  • MBWR (Modified Benedict-Webb-Rubin type, Jacobsen 32-coefficients, NIST recommended).
  • Lee-Kesler (generalized Benedict-Webb-Rubin).
  • Peng-Robinson
  • Soave-Redlich-Kwong
  • Redlich-Kwong
  • Van der Waals
  • Ideal gas

Analysis temperatures are achieved either by recirculator bath (-20oC to 100oC, see below), cryocooler (77K-320K), or heating mantle (up to 400oC).

This excess adsorption isotherm goes through a maximum. Click to enlargeUsing the correct equation of state (EOS) is essential. Click to enlarge.

 

pdfBrochure Specifications Technology
BoosterGas pressure booster increases cylinder pressure from 55bar to 200bar.

This compensates for the drop in pressure from a standard laboratory cylinder as gas is used for analyses and ensures a constant supply of high pressure gas.

RecirculatorIsotherms can be measured from -20 to +100C with this recirculator.

This liquid chiller/heater
/circulator provides stable sample temperatures from -20oC up to 100oC set via PC. Includes jacketed cell.

CryoCoolerCryoCooler

Cryogen-free sample thermostating option for the iSorbHP. The Cryo-Cooler allows gas sorption studies to be run at temperatures between 77K to 320K.

Distributor’s page:

 

CORPORATE HEADQUARTERS
QUANTACHROME INSTRUMENTS
1900 Corporate Drive
Boynton Beach, Florida 33426 USA

Tel: 1-561-731-4999
Fax: 1-561-732-9888

U.S. and Canada Toll-free
1-800-989-2476
www.quantachrome.com
EUROPE
QUANTACHROME UK Ltd.
Pale Lane Farm, Pale Lane
Hartley Wintney, Hook RG27 8DH
England

Tel: 01252 819719
Fax: 01252 819901
www.quantachrome.co.uk

QUANTACHROME GmbH & Co. KG
Rudolf-Diesel Str. 12,
85235 Odelzhausen
Germany

Tel: 08 134/93240
Fax: 08 134/932425
www.quantachrome.de/
CHINA

QUANTACHROME REPRESENTATIVE OFFICE
M806. Jingbao Garden
183 Andingmenwai Street
Beijing 100011
China

Tel: + 86 800 810 0515, + 86 10 64400892, + 86 13 801191442
Fax: +86 10 64400892
www.quantachrome-china.com

Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: